HPM2.C - Heat pump system consisting of the external unit HPMO2 and the internal 3in1 type HPMD...
HPM2.V
HPM2.V - integrated set consisting of an external unit HPMO2, internal unit HPMI2 for installation in new and modernized installations, and a combined "all in one" 2-in-1 SWVPC tank providing hot water even for up to 4 people.
HPM2.V System includes:
- external unit HPMO2
- internal unit type HPMI2
- combined "all in one" 2-in-1 SWVPC tank
Description
Sets
Technical data
Additional equipment
Download
Product Details
HPMI2 Internal Unit
Heating central unit with weather control, equipped with a hydraulic group and an electric heating assembly.
- Quick installation thanks to compact housing and fitted components.
- Advanced control capabilities:
- Weather-based heating control.
- Daily and weekly temperature regulation cycles for room and hot water.
- Control of 2 heating circuits + hot water circuit.
- Electric heating assembly with automatic power modulation:
- **3/6 kW for HPMO2-8 and HPMO2-12.
- ***3/6/9 kW for HPMO2-16/23.
- Hydraulic group:
- Three-way diverting valve that enables water heating in cooperation with the DHW heat exchanger.
- Safety group - 12L expansion vessel, safety valve, electronic pressure gauge, automatic air vent.
- Remote internet control using the C.MI2 module (additional equipment).
HPM2 External Unit
Pump installation is easier thanks to the built-in hydraulic group. The devices included in it are essential for the correct operation of the installation. The hydraulic group includes:
- Energy class: A+++(35°C)/A++(55°C).
- Coolant R32.
- EVI injection system ensures high operating efficiency and water temperature up to 60°C.
- Wide operating range at outdoor air temperatures from -25°C to +43°C.
- Quiet operation - acoustic pressure level at a distance of 1m: 52 to 56 dB(A) depending on the selected unit power - Q2 coefficient.
- Room cooling or cooperation with a fan coil unit + Anti-freeze condensate protection.
- Smooth power modulation ensures optimal operation depending on heating needs from 2.3 to 8.2kW (A7/W35).
Combined Tank "all in one” 2-in-1 SWVPC
The combined tank combines a DHW heat exchanger with a central heating buffer tank that supports heating and cooling of spaces. The tank has a double coil "Double Coil" with a surface area of 2.7 m2.
Double Coil:- Special construction - two coils connected by a collector provide high flow and heating surface, guaranteeing the highest pump efficiency.
- A partition in the central heating buffer tank prevents mixing of hot supply water for the central heating system with cold water returning to the buffer.
- Compact design allows for simplified installation in small or tight spaces, while the capacity ensures hot water comfort even for a family of 4.
- The ABS housing is durable and protects the tank from mechanical damage, and the material does not age during years of use.
Watch the Video and Discover the KOSPEL Heat Pump Heating System
HPM2.V-8 | HPM2.V-12 |
---|---|
Heat pump system includes:
|
Heat pump system includes:
|
Optimal amount of hot water for 3-4 people. | Optimal amount of hot water for 3-4 people. |
Product Code | HPM2.V-8 | HPM2.V-12 |
---|---|---|
Energy Efficiency Class | A+++ (35°C) / A++ (55°C) | A+++ (35°C) / A++ (55°C) |
Maximum Heat Pump Heating Power (kW) | 5.8 (A-7/W35) 7.1 (A+2/W35) 8.2 (A+7/W35) |
9.2 (A-7/W35) 11.3 (A+2/W35) 12.5 (A+7/W35) |
COP Efficiency Factor for: | 4.6 (A+7/W35) 4.01 (A+2/W35) 3.49 (A-7/W35) |
4.75 (A+7/W35) 3.94 (A+2/W35) 3.37 (A-7/W35) |
Acoustic Power Level dB (A) | 60 | 63 |
Max Acoustic Pressure Level dB(A) - Coefficient Q2 | 52 | 55 |
Power Supply | 400 V 3N~ / 230 V~ | 400 V 3N~ / 230 V~ |
Max Heating Medium Temperature | 60°C | 60°C |
Rated Current of Overcurrent Switch | 3x16A / 40A | 3 x 25 A / 50 A |
Min. Supply Cable Cross-Section | 5 x 2.5 mm2 / 3x6 mm2 | 5 x 2.5 mm2 / 3x6 mm2 |
Total Heat Exchanger Capacity | 235 | 235 |
Heat Exchange Surface (m2) | 2.7 | 2.7 |
Coil Power (kW) | 75 / 23 | 75 / 23 |
Insulation Thickness (mm) | 67 | 67 |
Insulation Material | PUR | PUR |
Possibility of Using a Heater | ||
Buffer Tank Capacity (L) | 60 | 60 |
Buffer Tank Insulation Thickness (mm) | 67 | 67 |
Product Code | Description |
C.MI2 | The C.MI2 internet module allows remote control of the heat pump via the internet using a computer, tablet, or smartphone. Control is done through a web browser, providing easy and intuitive operation, as well as access to all advanced device control functions. |
HP.FF | Vibration isolation stand (base) for the heat pump 600x190x200 (2 pieces in the set). |
WE-019/01 | Temperature sensor for the storage tank / buffer. |
WE-019/05 | Temperature sensor for the heating circuits. |
HP.HS.24 | 24V humidity switch to protect against moisture accumulation. |