HPM2.C - Heat pump system consisting of the external unit HPMO2 and the internal 3in1 type HPMD...
HPM2.P
HPM2.P - integrated set consisting of an external unit HPMO2, an internal unit HPMI2 for installation in new and modernized installations, a central heating buffer SVK, and a domestic hot water heat exchanger SWPC, providing hot water even for 7 people.
The HPM2.P system includes:
- external unit HPMO2
- internal unit of type HPMI2
- central heating buffer SVK
- domestic hot water heat exchanger SWPC
Description
Sets
Technical data
Additional equipment
Download
Product Details
HPMI2 Internal Unit
Central heating unit with weather control, equipped with a hydraulic group and an electric heating assembly
- Quick installation thanks to compact housing with fitted components
- Advanced control capabilities:
- Weather control of heating
- Daily and weekly temperature regulation cycles in rooms and hot water
- Control of 2 heating circuits + hot water circuit
- Electric heating assembly with automatic power modulation:
- **3/6 kW for HPMO2-8 and HPMO2-12
- ***3/6/9 kW for HPMO2-16/23
- Hydraulic group:
- Three-way diverter valve that allows water heating in cooperation with the hot water exchanger
- Safety group - 12-liter expansion vessel, safety valve, electronic pressure gauge, automatic air vent
- Remote control via the internet using the C.MI2 module (additional equipment).
HPM2 External Unit
Pump installation is easier thanks to the built-in hydraulic group. The devices included in it are necessary for the correct operation of the installation. The hydraulic group includes:
- Energy class: A+++(35 °C)/A++ (55 °C)
- Coolant: R32
- EVI injection system ensures high work efficiency and water temperature up to 60°C
- Wide operating range at an external air temperature from -25°C to +43°C
- Quiet operation of the device - acoustic pressure level at a distance of 1m: 52 to 56 dB(A) depending on the selected device power - coefficient Q2
- Flat space heating or cooperation with a fan coil unit + Protection against freezing of condensate
- Smooth power modulation ensures optimal operation depending on heating needs from 2.3 to 8.2 kW (A7/W35)
SVK Central Heating Buffer
- Capacity: 104 liters
- Energy class A - very good thermal insulation (PUR foam 65mm)
- Accumulates heat in heating mode and cold in cooling mode
- Extends the reliable operation time of the compressor by limiting the number of starts during transitional periods: spring - autumn
- Supports the "defrost" function of the compressor without drawing energy from the heating circuits
- Ensures optimal system operation by separating the hydraulic pump circuit from the heating circuits
SWPC Domestic Hot Water Heat Exchanger
Heat exchanger with the largest heating surface
- Capacity: 300 liters, optimal for a 5-7 person family
- Special design with two coils connected to a collector ensures a large flow and a heating surface of 4.22 m2. This guarantees the highest pump efficiency.
- Possibility of connecting 1 or 2 additional electric heaters
Watch the video and learn about the Kospel heat pump heating system
HPM2.P-8 | HPM2.P-12 | HPM2.P-16 |
---|---|---|
Heat pump system includes:
|
Heat pump system includes:
|
Heat pump system includes:
|
Optimal amount of domestic hot water for 5-7 persons. | Optimal amount of domestic hot water for 5-7 persons. | Optimal amount of domestic hot water for 5-7 persons. |
Product Code | HPM2.C-8 | HPM2.C-12 | HPM2.C-16 |
---|---|---|---|
Energy Efficiency Class | A+++ (35 °C) / A++ (55 °C) | A+++ (35 °C) / A++ (55 °C) | A+++ (35 °C) / A++ (55 °C) |
Maximum Heat Pump Power (kW) | 5.8 (A-7/W35) 7.1 (A+2/W35) 8.2 (A+7/W35) |
9.2 (A-7/W35) 11.3 (A+2/W35) 12.5 (A+7/W35) |
17.1 (A-7/W35) 20.5 (A+2/W35) 23.0 (A+7/W35) |
Efficiency COP to: | 4.6 (A+7/W35) 4.01 (A+2/W35) 3.49 (A-7/W35) |
4.75 (A+7/W35) 3.94 (A+2/W35) 3.37 (A-7/W35) |
4.76 (A+7/W35) 4.02 (A+2/W35) 3.47 (A-7/W35) |
Sound Power Level dB (A) | 60 | 63 | 64 |
Max Acoustic Pressure Level dB(A) - Q2 coefficient | 52 | 55 | 56 |
Power Supply | 400 V 3N~ / 230 V~ | 400 V 3N~ / 230 V~ | 400 V 3N~~ |
Max Heat Carrier Temperature | 60oC | 60oC | 60oC |
Nominal Overcurrent Protection Current | 3x16A / 40A | 3 x 25 A / 50 A | 3 x 32A |
Min. Power Cable Cross-Section | 5 x 2.5 mm2 / 3x6 mm2 | 5 x 2.5 mm2 / 3x6 mm2 | 5 x 2.5 mm2 |
Total Heat Exchanger Capacity | 305 | 305 | 305 |
Heat Exchange Surface Area (m2) | 4.22 | 4.22 | 4.22 |
Coil Power (kW) | 120 / 36 | 120 / 36 | 120 / 36 |
Insulation Thickness (mm) | 67 | 67 | 67 |
Insulation Material | PUR | PUR | PUR |
Possibility of Using Heater | |||
Buffer Tank Capacity (L) | 60 | 60 | 60 |
Buffer Tank Insulation Thickness (mm) | 65 | 65 | 65 |
Product Code | Description |
C.MI2 | The C.MI2 internet module allows remote control of the heat pump via the internet using a computer, tablet, or smartphone. Control is done through a web browser, providing easy and intuitive operation, as well as access to all advanced device control functions. |
HP.FF | Vibration isolation stand (base) for the heat pump 600x190x200 (2 pieces in the set). |
WE-019/01 | Temperature sensor for the storage tank / buffer. |
WE-019/05 | Temperature sensor for the heating circuits. |
HP.HS.24 | 24V humidity switch to protect against moisture accumulation. |
You might also like
HPM2.Z - an integrated set consisting of the external unit HPMO2 and the internal unit HPMI2 for...
HPM2.V - integrated set consisting of an external unit HPMO2, internal unit HPMI2 for...